Aico MCP401RC Hard Wired Manual Call Point – 230V Mains Powered, Resettable Fire Alarm Call Point
SKU: MCP401RC

Aico
The Aico MCP401RC Hard Wired Manual Call Point is a mains-powered emergency activation device designed to provide a convenient way to manually trigger compatible interconnected smoke, heat and carbon monoxide (CO) alarm systems.
Designed for use with compatible Aico 3000 Series and 140e Series alarms, the MCP401RC allows occupants to activate all alarms on the connected system by pressing its resettable front plate.
Aico MCP401RC Hard Wired Manual Call Point – 230V Mains Powered, Resettable Fire Alarm Call Point
Aico MCP401RC Manual Call Point for Hard Wired Smoke, Heat and CO Alarm Systems
The Aico MCP401RC Hard Wired Manual Call Point is a mains-powered emergency activation device designed to provide a convenient way to manually trigger compatible interconnected smoke, heat and carbon monoxide (CO) alarm systems.
Designed for use with compatible Aico 3000 Series and 140e Series alarms, the MCP401RC allows occupants to activate all alarms on the connected system by pressing its resettable front plate.
When activated, the manual call point sends an interconnect signal, causing the connected alarms to sound simultaneously. This provides a straightforward method of raising an alarm throughout the interconnected system.
Unlike traditional break-glass call points, the Aico MCP401RC features a non-breaking, resettable plastic operating element. It mimics the feel of breaking glass while eliminating the need to replace the front plate after activation.
Once the call point has been operated, a visible warning flag appears to indicate that it has been activated.
The device can then be reset using the supplied key. Resetting automatically cancels the interconnect signal, allowing the connected alarms to stop sounding, provided no other alarm condition remains active.
Powered by a 230V AC mains supply, the MCP401RC also incorporates tamper-proof rechargeable lithium backup cells designed to last for the unit's 10-year operating life.
These backup cells provide up to two months of operation in the event of a mains power failure, helping maintain the manual alarm activation function during an interruption to the electrical supply.
The MCP401RC can be hard wired into a compatible alarm system using a simple three-core connection consisting of Live, Neutral and Interconnect.
It supports systems containing up to 20 compatible devices, including the MCP401RC, making it suitable for appropriately designed domestic and residential alarm installations.
Supplied with a 35mm deep surface mounting box, reset key, screws and fixings, the Aico MCP401RC provides a practical solution for electricians and fire alarm installers.
Manufactured in Ireland and backed by a 5-year manufacturer's guarantee, the MCP401RC offers reliable manual activation for compatible Aico interconnected alarm systems.
Key Features
- Aico MCP401RC Hard Wired Manual Call Point
- Manufacturer Part Number: MCP401RC
- Emergency manual alarm activation device
- Designed for compatible interconnected smoke, heat and CO alarm systems
- 230V AC mains powered
- Rechargeable lithium backup cells
- Backup operation for up to 2 months during mains failure
- Backup cells designed for the unit's 10-year operating life
- Compatible with Aico 3000 Series alarms
- Compatible with Aico 140e Series alarms
- Supports up to 20 compatible interconnected devices, including the call point
- Activates all connected alarms when operated
- Non-breaking, resettable front plate
- Simulates the feel of traditional break-glass operation
- No replacement glass required after activation
- Visible warning flag indicates activation
- Simple key-operated reset
- Automatically cancels the interconnect signal when reset
- Can be hard wired into a compatible interconnected system
- Simple three-core Live, Neutral and Interconnect connection
- Suitable for 0.75mm² or 1.00mm² cable, as specified by the manufacturer
- Supplied with 35mm deep surface mounting box
- Reset key included
- Screws and fixings included
- Compact 85 x 85 x 60mm dimensions
- Manufactured in Ireland
- 5-year manufacturer's guarantee
Manual Activation of Interconnected Alarm Systems
The Aico MCP401RC Manual Call Point provides a straightforward method of manually activating a compatible interconnected alarm system.
When the front plate is pressed, the call point sends an interconnect signal to the connected alarms.
This causes the alarms throughout the interconnected system to sound, helping alert occupants to a potential emergency.
Benefits of Manual Alarm Activation
- Allows occupants to trigger connected alarms manually
- Provides an additional means of raising an alarm
- Activates compatible interconnected alarms simultaneously
- Suitable for appropriately designed residential alarm systems
- Simple operation in an emergency
- Convenient wall-mounted activation point
- Supports coordinated alarm notification throughout the property
The MCP401RC does not independently detect smoke, heat or carbon monoxide. It provides manual activation of compatible connected alarms.
Non-Breaking, Resettable Front Plate
One of the main advantages of the Aico MCP401RC is its innovative resettable operating element.
Traditional manual call points may use breakable glass that must be replaced after activation.
The MCP401RC instead features a durable, non-breaking plastic front plate that simulates the feel of breaking glass.
Once activated, the operating element can be reset using the supplied key.
Benefits of the Resettable Design
- No broken glass after activation
- No replacement front plate required following normal operation
- Quick and convenient resetting
- Reduced replacement component requirements
- Durable non-breaking plastic operating element
- Familiar manual call point operation
- Practical for testing and maintenance
This design provides the familiar operation of a manual call point while simplifying resetting and ongoing maintenance.
Visible Activation Warning Flag
The Aico MCP401RC features a visible warning flag that appears when the call point is activated.
This provides a clear indication that the device has been operated.
Benefits of the Activation Indicator
- Visually identifies an activated call point
- Helps installers and maintenance personnel identify the operated device
- Supports straightforward system checks
- Makes the activation status easier to recognise
- Complements the resettable operating mechanism
The warning flag remains visible until the device is reset using the appropriate key.
Simple Key-Operated Reset
After the MCP401RC Manual Call Point has been activated, it can be reset using the supplied reset key.
Resetting restores the operating element and automatically cancels the interconnect signal generated by the call point.
If no other alarm condition is present, the connected alarms will stop sounding.
Benefits of Key Resetting
- Quick restoration after activation
- No glass replacement required
- Reset key supplied
- Automatically cancels the manual interconnect signal
- Suitable for routine testing and maintenance
- Helps prevent unauthorised resetting
Replacement reset keys are available separately under Aico product code MCPSK2.
Compatible with Aico 3000 Series and 140e Series Alarms
The Aico MCP401RC is designed for use with compatible mains-powered Aico alarm systems.
The manufacturer specifies compatibility with:
- Aico 3000 Series smoke alarms
- Aico 3000 Series heat alarms
- Aico 3000 Series carbon monoxide alarms
- Aico 140e Series smoke alarms
- Aico 140e Series heat alarms
- Aico 140e Series carbon monoxide alarms, where applicable and compatible
The system supports a maximum of 20 compatible interconnected devices, including the MCP401RC.
Benefits of Aico Alarm Compatibility
- Integrates with compatible Aico interconnected alarm systems
- Provides manual activation alongside automatic detection
- Suitable for new installations
- Useful for upgrading compatible existing systems
- Supports interconnected alarm notification
- Practical for domestic and residential applications
Important: Compatibility must be checked against the exact alarm models and the manufacturer's current interconnection instructions. The MCP401RC should not be assumed compatible with every Aico alarm or third-party fire alarm system.
230V Mains Powered with Rechargeable Battery Backup
The Aico MCP401RC operates from a 230V AC mains supply.
It also incorporates tamper-proof rechargeable lithium backup cells designed to provide continued operation during a mains power failure.
The manufacturer specifies that the backup cells are designed to last for the 10-year operating life of the unit.
They can provide up to two months of backup operation when mains power is unavailable.
Benefits of Mains Power with Battery Backup
- Reliable mains-powered operation
- Backup operation during electrical supply interruptions
- Rechargeable lithium backup cells
- Backup cells designed for the unit's operating life
- Reduced routine battery replacement requirements
- Suitable for compatible mains-powered alarm systems
Important: The stated backup duration is a maximum manufacturer figure and depends on operating conditions. The backup supply supports the call point itself; it does not independently guarantee that every interconnected alarm will remain operational during a mains failure.
Easy Three-Core Hard Wired Interconnection
The Aico MCP401RC is designed for straightforward integration into compatible hard wired alarm systems.
It uses the same basic three-core connection arrangement as the supported Aico smoke, heat and CO alarms.
Electrical Connections
- Live (L)
- Neutral (N)
- Interconnect (IC)
The manufacturer specifies the use of 0.75mm² or 1.00mm² cable for the connection.
The call point can be hard wired into a suitable position within the compatible interconnected system.
Benefits of Hard Wired Interconnection
- Reliable wired alarm communication
- No separate wireless pairing required
- Suitable for compatible mains-powered alarm systems
- Straightforward three-core connection
- Can be integrated into existing compatible systems
- Practical for professional electrical installation
The system must be wired in accordance with Aico's installation instructions and applicable electrical regulations.
Suitable for Up to 20 Interconnected Devices
The Aico MCP401RC supports compatible interconnected alarm systems containing up to 20 devices in total, including the manual call point.
This makes it suitable for properties requiring multiple interconnected smoke, heat and CO alarms.
Typical Interconnected System Applications
Depending on the installation design, a compatible system may include:
- Smoke alarms in circulation areas
- Smoke alarms on upper floors
- Heat alarms in kitchens
- Carbon monoxide alarms in suitable locations
- Additional compatible alarms
- MCP401RC manual call point
When the MCP401RC is activated, it sends the interconnect signal to the compatible connected alarms.
Important: The 20-device maximum includes the MCP401RC itself. Any additional manual call points or interconnected devices must be counted towards the manufacturer's permitted system limit.
Supplied with 35mm Surface Mounting Box
The Aico MCP401RC Manual Call Point is supplied with a 35mm deep surface mounting box.
This provides a practical mounting arrangement for suitable installations.
The product also includes the required reset key and installation fixings.
Supplied Accessories
- Aico MCP401RC Manual Call Point
- 35mm deep surface mounting box
- Reset key
- Screws
- Fixings
Installation Benefits
- Surface mounting box included
- Suitable for professional wall installation
- No separate reset key purchase required for initial installation
- Fixings supplied
- Practical for new and existing compatible alarm systems
The mounting position must be selected according to the installation design and applicable fire safety requirements.
Compact and Practical Design
The Aico MCP401RC features compact dimensions of 85 x 85 x 60mm.
Its practical wall-mounted design allows it to be positioned at a suitable manual activation point within the property.
Product Dimensions
- Height: 85mm
- Width: 85mm
- Depth: 60mm
Benefits of the Compact Design
- Practical wall-mounted installation
- Suitable for residential alarm systems
- Easy-to-identify manual activation point
- Compact enclosure
- Surface mounting box supplied
- Suitable for professional electrical installation
The call point should be installed in a visible, accessible location appropriate to the property's fire safety arrangements.
Ideal for Residential Fire Alarm Installations
The Aico MCP401RC is particularly useful for residential alarm systems where a manually operated activation point is required.
Its compatibility with selected Aico smoke, heat and CO alarms makes it a practical addition to appropriately designed interconnected systems.
Typical Applications
- Houses
- Flats and apartments
- Residential developments
- Property refurbishments
- Domestic alarm system upgrades
- Suitable multi-occupancy residential properties
- New-build residential installations
- Compatible hard wired smoke alarm systems
- Compatible interconnected heat alarm systems
- Compatible interconnected CO alarm systems
Important: The MCP401RC is intended for compatible Aico interconnected alarm systems. It is not a direct substitute for a conventional fire alarm system manual call point unless the complete system design and applicable standards specifically permit its use.
Manufactured in Ireland
The Aico MCP401RC Manual Call Point is manufactured in Ireland.
It is designed to complement compatible Aico smoke, heat and carbon monoxide alarm systems.
Its mains-powered operation, rechargeable backup cells and resettable mechanism make it a practical choice for installers seeking an integrated manual alarm activation device.
- Brand: Aico
- Manufacturer: Aico
- Product Code / SKU: MCP401RC
- Product Type: Hard Wired Manual Call Point
- Primary Function: Manual Activation of Compatible Interconnected Alarms
- Power Supply: 230V AC Mains
- Backup Power: Rechargeable Lithium Cells
- Backup Cell Type: Tamper-Proof Rechargeable Lithium
- Backup Cell Design Life: 10 Years
- Maximum Backup Operating Duration: Up to 2 Months During Mains Failure
- Operating Element: Non-Breaking Resettable Plastic Front Plate
- Break-Glass Replacement Required: No
- Activation Method: Press Front Plate
- Activation Indicator: Visible Warning Flag
- Reset Method: Key Operated
- Reset Key Included: Yes
- Replacement Reset Key Code: MCPSK2
- Interconnection Type: Hard Wired
- Connection Arrangement: 3-Core
- Electrical Connections: Live, Neutral and Interconnect
- Specified Cable Sizes: 0.75mm² or 1.00mm²
- Maximum Interconnected Devices: 20, Including MCP401RC
- Compatible Alarm Range: Aico 3000 Series
- Compatible Alarm Range: Aico 140e Series
- Compatible Alarm Types: Selected Smoke, Heat and Carbon Monoxide Alarms
- Installation Type: Surface Mounted
- Surface Mounting Box Included: Yes
- Surface Mounting Box Depth: 35mm
- Fixings Included: Yes
- Height: 85mm
- Width: 85mm
- Depth: 60mm
- Dimensions (H x W x D): 85 x 85 x 60mm
- Weight Including Packaging: 230g
- Manufacturer's Guarantee: 5 Years
- Country of Manufacture: Ireland
- Standalone Smoke Detection: No
- Standalone Heat Detection: No
- Standalone CO Detection: No
- Wireless Interconnection: Not Specified; Designed for Hard Wired Interconnection
Suitable Applications
The Aico MCP401RC Hard Wired Manual Call Point is suitable for appropriately designed alarm installations, including:
- Residential Fire Alarm Systems
- Domestic Smoke Alarm Systems
- Hard Wired Smoke Alarm Installations
- Interconnected Heat Alarm Systems
- Compatible Carbon Monoxide Alarm Systems
- Aico 3000 Series Alarm Installations
- Aico 140e Series Alarm Installations
- Manual Alarm Activation Points
- Residential Alarm System Upgrades
- New-Build Housing Developments
- House Renovations
- Flats and Apartments
- Suitable Multi-Occupancy Residential Properties
- Property Refurbishment Projects
- Electrical Contractor Installations
- Alarm System Maintenance
- Replacement Manual Call Points
- Residential Fire Safety Improvements
Important: Suitability depends on the specific interconnected alarm system, property requirements and applicable fire safety standards.
Why Choose the Aico MCP401RC Hard Wired Manual Call Point?
The Aico MCP401RC Manual Call Point provides a convenient and reliable way to manually activate compatible interconnected smoke, heat and CO alarms.
Its non-breaking, resettable front plate offers the familiar feel of a traditional break-glass call point without requiring replacement glass after activation.
When pressed, the MCP401RC triggers all compatible alarms on the connected system, providing a straightforward means of raising an alarm throughout the property.
The visible activation flag clearly indicates when the call point has been operated.
A supplied reset key allows the device to be restored quickly, automatically cancelling the interconnect signal.
The 230V mains supply provides normal operating power, while the integrated rechargeable lithium backup cells provide up to two months of operation during mains failure.
Its compatibility with selected Aico 3000 Series and 140e Series alarms makes it a practical addition to suitable hard wired alarm systems.
The simple Live, Neutral and Interconnect wiring arrangement supports straightforward professional installation.
Supplied with a 35mm surface mounting box, reset key and fixings, the MCP401RC includes the main accessories needed for its intended mounting arrangement.
With a 10-year designed operating life, 5-year manufacturer's guarantee and manufacture in Ireland, the Aico MCP401RC is an excellent choice for electricians, alarm installers and property developers requiring a dependable manual activation point for compatible Aico alarm systems.