Lewden BRCBO-B16/30/1HP 16A B Curve 30mA Type B-HP Heat Pump RCBO 6kA
SKU: BRCBO-B16/30/1HP

Lewden
The Lewden BRCBO-B16/30/1HP is a specialist 16A B Curve Type B-HP RCBO designed for heat pump installations requiring enhanced residual-current protection. Combining 30mA RCD protection with overload and short-circuit protection in one compact device, it provides a space-saving solution for compatible heat pump circuits
Lewden BRCBO-B16/30/1HP 16A B Curve 30mA Type B-HP Heat Pump RCBO 6kA
Enhanced Type B RCBO Protection for Heat Pump Installations
The Lewden BRCBO-B16/30/1HP is a specialist 16A B Curve Type B-HP RCBO designed for heat pump installations requiring enhanced residual-current protection. Combining 30mA RCD protection with overload and short-circuit protection in one compact device, it provides a space-saving solution for compatible heat pump circuits.
Part of Lewden's specialist B-HP Heat Pump RCBO range, this 16A model is designed to accommodate the higher-frequency residual currents that can occur with modern inverter-driven heat pump technology. Its compact 18mm single-module design also removes the need for the separate MCB required when using a Type B RCCB.
Key Features
- Lewden B-HP Heat Pump RCBO
- Product code BRCBO-B16/30/1HP
- 16A rated current
- B Curve overcurrent characteristic
- Enhanced Type B / Type B-HP residual-current protection
- 30mA residual-current rating
- 6kA short-circuit breaking capacity
- Purpose-designed for heat pump applications
- Designed for higher-frequency residual currents
- Operational at frequencies of 20kHz and above
- Combines RCD and overcurrent protection
- Bi-directional operation
- 1 pole + switched neutral
- Compact 1-module construction
- Only 18mm wide
- DIN rail mounting
- Compatible with suitable Lewden consumer units
- Certified to BS EN/IEC 61009-1
- Certified to BS EN/IEC 62423
- Operating temperature from -25°C to +40°C
Designed Specifically for Heat Pump Circuits
Modern heat pumps frequently incorporate inverter technology and electronic power-control systems. These components can produce residual-current waveforms at frequencies considerably higher than the normal mains frequency.
Many heat pump manufacturers consequently specify Type F or Type B residual-current protection, while some require an enhanced Type B device capable of catering for higher-frequency leakage currents.
The Lewden B-HP range has been developed specifically for these applications, providing a dedicated protective solution where the heat pump manufacturer's requirements call for its enhanced Type B characteristics.
Enhanced Type B-HP Residual-Current Protection
The BRCBO-B16/30/1HP provides Lewden's specialist Type B-HP residual-current protection.
Some heat pump manufacturers require an enhanced Type B RCD capable of catering for frequencies up to 20kHz, with a minimum trigger point of 150mA above 1kHz. Lewden specifies its B-HP RCBO technology as operational at frequencies of 20kHz and above.
This enhanced high-frequency capability makes the device particularly relevant for heat pumps where conventional residual-current protection does not meet the equipment manufacturer's specified requirements.
16A B Curve Overcurrent Protection
This variant has a 16A rated current with a B Curve overcurrent characteristic, making it suitable for correctly designed heat pump circuits requiring these particular characteristics.
The two "B" designations should not be confused. B Curve describes the overcurrent tripping characteristic, whereas Type B-HP relates to the RCBO's residual-current detection characteristics.
The protective device should always be selected according to the heat pump manufacturer's requirements, circuit design, cable characteristics and applicable wiring regulations.
30mA Residual-Current Protection
The BRCBO-B16/30/1HP has a 30mA rated residual operating current, combining additional residual-current protection with Lewden's enhanced B-HP characteristics.
This makes it a compact solution where both 16A overcurrent protection and 30mA Type B-HP residual-current protection are required from the same device.
RCD & Overcurrent Protection in One Device
As an RCBO, the BRCBO-B16/30/1HP combines:
- Residual-current protection
- Overload protection
- Short-circuit protection
This offers a significant installation advantage over a Type B RCCB, which provides residual-current protection but requires appropriate separate overcurrent protection.
Lewden's B-HP RCBO therefore eliminates the need for an additional MCB solely to provide the overcurrent protection required alongside an RCCB.
Compact 18mm Single-Module Design
One of the key advantages of the Lewden B-HP range is its exceptionally compact 1-module, 18mm construction.
A Type B RCCB combined with an appropriate MCB can occupy approximately three consumer-unit modules. The BRCBO-B16/30/1HP provides residual-current and overcurrent protection within just one 18mm module.
This makes it particularly useful for heat pump installations where available consumer-unit capacity is limited.
6kA Short-Circuit Breaking Capacity
The BRCBO-B16/30/1HP provides a 6kA short-circuit breaking capacity, alongside its overload and residual-current protection.
The integrated design provides the principal RCBO protective functions within one device, reducing the number of individual protective devices required for a correctly designed circuit.
Bi-Directional Operation
The Lewden B-HP RCBO range features bi-directional operation, providing greater flexibility within suitable electrical installations.
Combined with its enhanced Type B-HP characteristics, this makes the device well suited to modern electrical systems incorporating sophisticated electronic equipment.
1 Pole + Switched Neutral
The BRCBO-B16/30/1HP uses a 1 pole plus switched neutral configuration while retaining its compact single-module dimensions.
This provides switched-neutral functionality without requiring additional DIN rail space within the consumer unit.
Compatible with Lewden Consumer Units
Lewden B-HP RCBOs are designed for installation within a standard Lewden RCBO consumer unit.
They can also be installed as one of the High Integrity circuits within compatible Lewden:
- Dual RCCB consumer units
- Split Load consumer units
- Dual Tariff consumer units
This provides flexibility when installing a new dedicated heat pump circuit or incorporating heat pump protection into suitable existing Lewden distribution equipment.
Certified to Relevant Standards
The Lewden B-HP Heat Pump RCBO range is specified as certified to:
BS EN/IEC 61009-1 – covering residual-current operated circuit breakers with integral overcurrent protection.
BS EN/IEC 62423 – covering additional requirements associated with Type F and Type B residual-current operated circuit breakers.
The specified operating temperature range is -25°C to +40°C.
- Brand: Lewden
- Range: B-HP Heat Pump RCBO
- Product Code: BRCBO-B16/30/1HP
- Product Type: Heat Pump RCBO
- RCD Classification: Enhanced Type B / Type B-HP
- Rated Current: 16A
- Trip Curve: B Curve
- Rated Residual Current: 30mA
- Short-Circuit Breaking Capacity: 6kA
- Pole Configuration: 1 Pole + Switched Neutral
- Bi-Directional: Yes
- Module Width: 1 Module
- Width: 18mm
- Residual-Current Protection: Yes
- Overload Protection: Yes
- Short-Circuit Protection: Yes
- High-Frequency Operation: 20kHz and Above
- Mounting: DIN Rail
- Operating Temperature: -25°C to +40°C
- Standards: BS EN/IEC 61009-1 & BS EN/IEC 62423
- Primary Application: Heat Pump Circuit Protection
- Consumer Unit Compatibility: Suitable Lewden RCBO Consumer Units & Compatible High Integrity Ways
Suitable Applications
- Air Source Heat Pumps
- Ground Source Heat Pumps
- Inverter-Driven Heat Pumps
- Domestic Heat Pump Systems
- Commercial Heat Pump Systems
- Dedicated 16A Heat Pump Circuits
- Low-Carbon Heating Systems
- Renewable Heating Installations
- Residential Electrical Installations
- Commercial Electrical Installations
- Lewden Consumer Units
- High Integrity Consumer Unit Circuits
- Heat Pumps Requiring Enhanced Type B Protection
Why Choose the Lewden BRCBO-B16/30/1HP?
The Lewden BRCBO-B16/30/1HP provides a specialist protective solution for heat pump circuits requiring an enhanced Type B residual-current characteristic.
It combines 16A B Curve overcurrent protection, 30mA residual-current protection and a 6kA short-circuit breaking capacity in a single RCBO. The specialist Type B-HP characteristic is designed to accommodate the higher-frequency residual currents associated with certain modern heat pump systems.
Its 18mm single-module design is also a major practical advantage. Rather than using a Type B RCCB together with a separate MCB, installers can provide both residual-current and overcurrent protection from one compact protective device.
With bi-directional operation, 1 pole plus switched neutral configuration and compatibility with suitable Lewden consumer units, the BRCBO-B16/30/1HP provides a neat and space-efficient solution where its particular B-HP protection characteristics are specified by the heat pump manufacturer and electrical design.